This product uses infrared receiving technology and environmental compensation algorithms to measure human body temperature or object temperature, while using distance sensors to compensate for temperature, achieving more accurate measurement. When in use, simply align the detection window with the measurement position to quickly and accurately measure the temperature of the human body or object.
This product has the characteristics of wide measurement range, high accuracy, convenient use, easy installation, and high cost-effectiveness.
Suitable for infrared thermometers, temperature gates, facial recognition temperature measurement all-in-one machines, turnstiles, robots, area monitoring, and high-precision non-contact temperature measurement equipment.
1. Default baud rate 115200, check bit N, data bit 8, stop bit 1;
2. Baud rate change setting:
A. Set module communication baud rate 9600
Main control sends: 0xf0 0x4F 0x06 0Xef 0XEE
The slave does not respond and needs to be powered off and restarted in order for the baud rate setting to take effect
B. Set module communication baud rate 19200
Main control sends: 0xf0 0x4F 0x07 0Xef 0XEE
The slave does not respond and needs to be powered off and restarted to activate the baud rate setting
C. Set module communication baud rate of 38400
Main control sends: 0xf0 0x4F 0x08 0Xef 0XEE
The slave does not respond and needs to be powered off and restarted to activate the baud rate setting
D. Set module communication baud rate 57600
Main control sends: 0xf0 0x4F 0x09 0Xef 0XEE
The slave does not respond and needs to be powered off and restarted to activate the baud rate setting
E. Set module communication baud rate of 115200
Main control sending: 0xf0 0x4F 0x0A 0Xef 0XEE
The slave does not respond and needs to be powered off and restarted to activate the baud rate setting
5、Serial protocol configuration
1、Obtain module temperature data (query method)
Main control sending:0XF0 0X4F 0X01 0XEF 0XEE;
2、Module reply:
Data 1: 0XF0
Data 2: 0X4F
Data 3: 0X00 The high byte of the length of all temperature data
Data 4:0X08 The low byte of the length of all temperature data
Data 5: 0X00-0XFF temperature high byte
Data 6: 0X00-0XFF Temperature Low Byte
Data 7: 0X00-0XFF ambient temperature high byte
Data 8: 0X00-0XFF ambient temperature low byte
Data 9:0X00-0XFF
Data 10:0X00-0XFF
Data 11:0X00-0XFF
Data 12:0X00-0XFF
Data 13:0XEF
Data 14:0XEE
Actual temperature high byte
Actual temperature low byte
Laser ranging distance high byte
Laser ranging distance low byte
End of frame
End of frame
6、 Outline dimension drawing (66 * 31 * 22mm)
7、 Wiring method (as shown in the figure below)
8、 Test value calculation method
1、Temperature calculation (the three temperature calculation methods are the same)
Shift the high temperature byte to the right by 8 bits (or multiply the high temperature byte by 256)+the low temperature byte, and then divide by 100 to obtain the result in degrees Celsius (℃)
2. Distance calculation
Shift the distance from the high byte by 8 bits to the right (or multiply the distance from the high byte by 256)+distance from the low byte; The obtained result is in millimeters (mm)
9、note
1. Before formal testing, it is best to power on and stabilize for 5 minutes;
2. Stay away from heat sources;
3. Used indoors, avoiding direct sunlight;
4. Prevent the probe from being compressed, covered with dust, and there should be no obstructions on the probe;
5. Do not obstruct the distance sensor.