<
>
  • Temperature and humidity transmitter BTH-2S

  • BTH-2S is an ultra-low power series temperature and humidity transmitter with an average power consumption of less than 0.02W, which is less than one tenth of that of similar products. Ultra low power consumption and unique air duct design completely solve the problem of circuit board temperature rise, with more accurate measurement and faster response characteristics.


Product manual

SPECIFICATION

product name:

Communication type temperature and humidity transmitter

Model

BTH-2S

version:

V1.0

Creator:

He Genwen

reviewed by:

Yuan Chao

 

1、 Overview

BTH-2S is an ultra-low power series temperature and humidity transmitter with an average power consumption of less than 0.02W, which is less than one tenth of that of similar products. Ultra low power consumption and unique air duct design completely solve the problem of circuit board temperature rise, with more accurate measurement and faster response characteristics. The use of second-generation sensor probes imported from Switzerland ensures excellent measurement performance of the product. Powerful functionality and stable performance, optional one or two switch outputs, unique control logic, can achieve multiple functional control and remote control, such as high temperature alarm, low temperature alarm, high humidity alarm, low humidity alarm, heating, cooling, humidification, dehumidification, etc.

 

2、  Application scope

Widely used in communication rooms, intelligent buildings, factory workshops, warehouses, drug depots, libraries, museums, laboratories, offices, ventilation ducts, greenhouses and other places.

 

3、  Product features

        Ultra low power consumption and unique air duct design prevent circuit temperature rise;

  • More accurate measurement and faster response;

  • LCD large screen display design, generous and beautiful;

  • Second-generation high-precision probes imported from Switzerland;

  • Password protection function to prevent unauthorized operations by non staff members;

  • Celsius and Fahrenheit can be switched, globally applicable;

  • Equipped with dew point analysis function;

  • Wall mounted ceiling structure design, easy to install;

  • Super stability and anti-interference ability;

  • High measurement accuracy, wide range, and good consistency;

  • The maximum communication distance can reach 1200 meters;

  • The product has strong protective performance and first-class lightning protection.

4、  Main technical parameters

rated voltage

DC9V~DC26V (recommended 12V)

 

measuring range

temperature:-20℃~80℃

humidity:0~100%rh

 

measurement accuracy

temperature: ±0.3℃ resolution ratio 0.1℃

humidity: ±3%rh  resolution ratio 0.1 rh

output interface

RS485

Communication protocol

MODBUS RTU

mail address

1-247,

BAUD

1200 bit/s,2400 bit/s, 4800 bit/s, 9600 bit/s, 19200 bit/s

Average Power

<0.02W,<2mA

Switching Output

Optional 1-2 switch outputs, default none

data record

Optional temperature and humidity data recording and event recording, default to none

Effective Working Area

10-20m2/piece

Installation method

Indoor wall installation, ceiling mounted installation

Product size

90*95*29mm

 

5、Key and setting operation instructions

On the initial page, pressing the "up" and "down" keys can switch the display: Td (dew point), ID (address), Baud (baud rate), DO1 (first switch status), DO2 (second switch status), Date (date, month, day), and time (hour: minute).

Setting operation: On the initial page, press the "Settings" prompt to enter the password. The initial password is "0000". At this time, the flashing bit can be adjusted by pressing the "+" and "-" keys, and can be shifted by pressing the "Settings" key. After entering the correct password, press the "Confirm" key to enter the settings. The parameter setting page consists of 22 pages, and pressing the "Up" and "Down" keys can select the item to be set, Press the "Confirm" button to set the parameters of the current project. After adjusting the parameters, press the "Confirm" button to save the settings, and then press the "Settings" button to return to the initial page. Keys and Settings

The page introduction is shown in the figure on the right:

Set project and corresponding page numbers

page number

Set Project

Explanation

page number

Set Project

Explanation

 

P:01

 

mail address

 

1-247

 

P:12

Low temperature lower limit value

Low temperature alarm value or under temperature

Limit value


 

P:02

 

BAUD

 

1200-19200

 

P:13

High humidity upper limit value

High humidity alarm value or humidity upper limit value

 

P:03

 

Parity

 

n81、o81、e81

 

P:14

Low temperature lower limit value

Low humidity alarm value or lower humidity limit value

 

P:04

 

temperature unit

C:centigrade;

          F:Fahrenheit degree

 

P:15

Temperature buffer value

Default 0.1 ℃, anti relay shake activated

 

P:05

 

DO1 use to

 

Ctrl:control model

Alar:Alarm mode

 

P:16

Humidity buffer value

Default 1 rh%, anti relay shake activation

P:06

DO2 use to

P:17

Date setting

Year, month, day

 

P:07

DO1 Function enabled

0 To deactivate

1 Enable

 

P:18

 

time setting

 

Hours, minutes, seconds

 

P:08

DO2 Function enabled

 

P:19

 

Password settings

 

0000-9999

 

P:09

 

DO1 state

 

 

OFF is normally open, ON is normally closed

 

P:20

Record cycle settings

 

Unit is in minutes, 1-180 can be set as

 

P:10

 

DO2 state

 

P:21

Zigbee

network ID

 

 

Zigbee wireless networking parameters

 

P:11

 

High temperature upper limit value

High temperature alarm value or upper temperature limit value

 

P:22

Zigbee

Network frequency band

 

6、Instruction of wiring

 

7、quality assurance

The warranty period is 12 months. During the quality assurance period, free maintenance services will be provided for the product based on normal use and non-human damage.

 

8、note

 

Do not install directly on heat sources, cold sources, or in direct sunlight;

Prohibit prolonged exposure to steam, water mist, water curtains, or condensation environments;

In dust or other polluted environments, products must be regularly cleaned.


  • Website homepage
  • Product Display
  • Qualification certificate
  • Application Information
  • Consulting
  • phone:0755-26588758 15013668479(倪先生) 13922884770(王先生)


    fax:0755-26747274


    mailbox:info@source-sensor.com


    address:East 3rd Floor, Building 15, Majialong Industrial Zone, Nantou Street, Nanshan District, Shenzhen


    Copyright©2002-2023 Yuanjian Sensing Technology . All Rights Reserved Copyright 粤ICP备17008245号-5 technical support:图页网 Website Map xml Website Map html