SPECIFICATION
product name: | Infrared temperature transmitter |
Model: | TIR-T0-D2-A-L1400 |
version: | V1.0 |
Creator: | He Genwen |
reviewed by: | Yuan Chao |
1 、 DESCRIPTION
TIR-T0-D2-A-L1400 is a high-performance remote non-contact infrared temperature measurement transmitter, with a beautiful and compact appearance, a threaded bracket structure design, simple wiring, easy installation, fast response speed, accurate temperature measurement, and non-contact measurement. It has strong stability and anti-interference ability, strong product protection performance, and is widely used in industrial, power and other applications that require high temperature monitoring.
2、 performance index
rated voltage | DC12~28V (recommendation DC24V) |
Infrared wavelength | 8- 14um |
measuring range | -20- 100℃ |
measurement accuracy | ±2℃Or the temperature being measured±2% |
Object distance ratio | D:S = 20:1 (Measurement distance: target diameter), converted to FOV of approximately 4 ° |
response time | <1s |
measurement resolution | 0.1℃ |
current output | 4-20mA (4mA—> -20℃, 20mA—> 100℃) |
Optional communication | UARTSerial port, used for command settings, detailed in "Communication Protocol" later on |
Working temperature and humidity | - 10~50℃ ,10-95%No condensation |
Storage temperature and humidity | -20~80℃, 45%RH No condensation |
3、 Installation dimensions
4、Electrical Interface Definition
Figure 1 Product Electrical Interface Diagram
Electrical interface information:
name | Color number | describe | types of | notes |
Power+ | red | 24V loop+ | Source |
|
Power- | black | 24V loop- | Source |
|
RXD | green | Module serial port reception | communicate | 3.3V TTL |
TXD | white | Module serial port transmission | communicate | 3.3V TTL |
GND | Yellow Green | Reference ground | Source |
|
Note: Power+and Power - are non-polar for module current output, corresponding to a two wire current output.
5、note
1、Keep the product body away from heat sources;
2、Used indoors, avoiding direct sunlight;
3、Prevent the probe from being compressed, covered with dust, and there should be no obstructions on the probe;
4、Cannot obstruct the distance sensor。
5、The product stabilizes after 5 minutes of power on