  • Micro pressure differential transmitter BPS-12A

  • The working principle of a micro pressure differential transmitter is that the pressure of the medium directly acts on the diaphragm of the sensor, causing the diaphragm to produce a micro displacement proportional to the pressure of the medium, causing a change in the resistance of the sensor. This change is detected by electronic circuits, and a standard signal corresponding to this pressure is converted and output.

Product manual

pic

SPECIFICATION

  • 1、Product Introduction

    The working principle of a micro pressure differential transmitter is that the pressure of the medium directly acts on the diaphragm of the sensor, causing the diaphragm to produce a micro displacement proportional to the pressure of the medium, causing a change in the resistance of the sensor. This change is detected by electronic circuits, and a standard signal corresponding to this pressure is converted and output.

    This product uses imported integrated chips, with wide voltage power supply, strong anti-interference ability, reverse connection protection, high accuracy, good stability, and can be manually corrected to zero.

    Micro pressure differential transmitter obtains the pressure difference between air and non corrosive gases, suitable for various industrial self-control environmental fields such as HVAC, dust-free and clean workshops, pipeline air supply, boiler negative pressure, oven pressurization, ventilation equipment, fan control, variable air volume systems, etc.

     

    2、Introduction to product components

     

    3、Model and Description

    4、Connection

     

    5、Product characteristics

    1. Linear pressure characteristics and selectable pressure measurement ranges

    2. Working voltage: 16-30VDC

    3. Signal output: 4-20mA/0-5V/0-10V/RS485 type

    4. zero adjustment

    5. Simple and fast installation brought by the integrated bracket inside the casing

    6. Calibration and temperature compensation measurement signals

     

    6、application area:

    1. Measure the subtle pressure difference in ventilation equipment and air conditioning ducts

    2. Check air flow rate

    3. Monitoring filters and controlling fans

     

    7、Model summary

    unit:Pa

    Product series

    product name

    Pressure range measurement

    measuring range 1

    measuring range 2

    measuring range 3

    measuring range 4

    Overload pressure

    Overload pressure

    BPS-01

    100Pa Micro pressure differential transmitter

    ±50Pa

     

    -

    ±65Pa

    ±100Pa

    ±10Kpa

    ±20Kpa

    BPS-02

    1KPa Micro pressure differential transmitter

    ±250Pa

     

    -

    ±500Pa

    ±1Kpa

    ±10Kpa

    ±20Kpa

    BPS-03

    10KPa Micro pressure differential transmitter

    ±2KPa

    ±3KPa

    ±5KPa

    ±10KPa

    ±85Kpa

    ±110Kpa

    BPS-04

    35Kpa Micro pressure differential transmitter

    ±30KPa

    ±35KPa

     

    -

     

    -

    ±175Kpa

    ±280Kpa

     

    8、Operating mode

    The sensor obtains the pressure difference through a silicon piezoresistive element, which forms a linear 4-20mA/0-5V/0-10V/RS485 temperature compensation output signal through the sensed deviation value。

     

    9、machine design

    The micro differential pressure transmitter consists of the following components:

    1. Sensor housing fixing bracket, cable entry, movable buckle with safety screws for pressing

    2. Force measurement using silicon piezoresistive elements

    3. Printed circuit board with wiring terminals and DIP switch for selecting measurement range (see debugging precautions)

    4. Zero adjustment button (see debugging precautions)

     

    10、Debugging precautions

    Adjustable measurement range: pressure range and direction, adjustable through a toggle switch

    Zero point adjustment: clearing and calibration

    Open the panel and press the zero adjustment button briefly (within 1 second) to reset it.

    (Please manually reset while parallel to the installation method; please manually reset while the positive and negative air intakes are connected.)

     

    Operation steps

    state

    result

    key

    1. PCB power on

    2. Keep the positive and negative pressure inlet pressure difference at zero

    3. Click the 0 button

     

     

    Red light on

     

     

    0 point calibration

     

     

    11、Technical Parameter

    Technical Parameter:

    measuring range

    Refer to "Model Summary"

    Sensing element

    Silicon piezoresistive element

    Room temperature

    Measurement during correct installation at 20-25 ℃ (FS=full range measurement)

    Precision: Total Error

    Temperature offset

    ± 1 % /± 0.5 % / ±0.2% FS

    <±0.1% FS /°C

    medium

    Air and non corrosive gases

    Permissible medium temperature range

    -20-85℃

    maintenance

    long term stability

    Electrical characteristics:

     

     

    All output types

    power supply

    safety extra low voltage

    voltage

    power dissipation

    DC16-30V

    <1.5 VA

     

     

     

    4-20mA type of output

    output current

    4-20 mA

    load

    ≤250 Ω

    output

    Non electric separation, non-polar two wire connection, rectifier bridge anti reverse connection

    link:

    Electrical connections

    screw terminal

    Maximum 1.5mm ² cable

    cable

    Cable sealing gland (without anti cable deformation)

    Pressure connection

    Pressure nozzle, 6.21 mm diameter

     

    ambient condition:

    Permissible ambient temperature

    run

    -20-85℃

    Transportation/Storage

    -40-125 ℃

    Permissible environmental humidity

    <90 % rh (No condensation)

     

    12、Appearance dimensions (length * width * height: 99.0 * 101.5 * 39.9mm, tolerance: ± 1mm)

     

    13、Installation method

     

  • First, use a ruler on the back to mark the installation hole position on the wall, drill a 30mm deep Ø 6mm wall hole to place the expansion pipe, then open the micro pressure differential transmitter buckle and flip over the cover

  • Cover and tighten the self tapping screw (ST3.5 × 25) Fix the micro pressure differential transmitter to the designated position on the wall through the fixing hole, connect the incoming and outgoing wires through the waterproof joint, and finally cover it with a cover.

  • Attention:

  • No air duct connection device is provided during supply;

  • Please carefully read the manual and follow the wiring diagram for operation. If the product is damaged due to wiring reasons, it cannot be guaranteed.



  • Website homepage
  • Product Display
  • Qualification certificate
  • Application Information
  • Consulting
  • phone:0755-26588758 15013668479(倪先生) 13922884770(王先生)


    fax:0755-26747274


    mailbox:info@source-sensor.com


    address:East 3rd Floor, Building 15, Majialong Industrial Zone, Nantou Street, Nanshan District, Shenzhen


    Copyright©2002-2023 Yuanjian Sensing Technology . All Rights Reserved Copyright 粤ICP备17008245号-5 technical support:图页网 Website Map xml Website Map html