1、Product Introduction
The working principle of a micro pressure differential transmitter is that the pressure of the medium directly acts on the diaphragm of the sensor, causing the diaphragm to produce a micro displacement proportional to the pressure of the medium, causing a change in the resistance of the sensor. This change is detected by electronic circuits, and a standard signal corresponding to this pressure is converted and output.
This product uses imported integrated chips, with wide voltage power supply, strong anti-interference ability, reverse connection protection, high accuracy, good stability, and can be manually corrected to zero.
Micro pressure differential transmitter obtains the pressure difference between air and non corrosive gases, suitable for various industrial self-control environmental fields such as HVAC, dust-free and clean workshops, pipeline air supply, boiler negative pressure, oven pressurization, ventilation equipment, fan control, variable air volume systems, etc.
2、Introduction to product components
3、Model and Description
4、Connection
5、Product characteristics
1. Linear pressure characteristics and selectable pressure measurement ranges
2. Working voltage: 16-30VDC
3. Signal output: 4-20mA/0-5V/0-10V/RS485 type
4. zero adjustment
5. Simple and fast installation brought by the integrated bracket inside the casing
6. Calibration and temperature compensation measurement signals
6、application area:
1. Measure the subtle pressure difference in ventilation equipment and air conditioning ducts
2. Check air flow rate
3. Monitoring filters and controlling fans
7、Model summary
unit:Pa
Product series | product name | Pressure range measurement |
measuring range 1 | measuring range 2 | measuring range 3 | measuring range 4 | Overload pressure | Overload pressure |
BPS-01 | 100Pa Micro pressure differential transmitter | ±50Pa | - | ±65Pa | ±100Pa | ±10Kpa | ±20Kpa |
BPS-02 | 1KPa Micro pressure differential transmitter | ±250Pa | - | ±500Pa | ±1Kpa | ±10Kpa | ±20Kpa |
BPS-03 | 10KPa Micro pressure differential transmitter | ±2KPa | ±3KPa | ±5KPa | ±10KPa | ±85Kpa | ±110Kpa |
BPS-04 | 35Kpa Micro pressure differential transmitter | ±30KPa | ±35KPa | - | - | ±175Kpa | ±280Kpa |
8、Operating mode
The sensor obtains the pressure difference through a silicon piezoresistive element, which forms a linear 4-20mA/0-5V/0-10V/RS485 temperature compensation output signal through the sensed deviation value。
9、machine design
The micro differential pressure transmitter consists of the following components:
1. Sensor housing fixing bracket, cable entry, movable buckle with safety screws for pressing
2. Force measurement using silicon piezoresistive elements
3. Printed circuit board with wiring terminals and DIP switch for selecting measurement range (see debugging precautions)
4. Zero adjustment button (see debugging precautions)
10、Debugging precautions
Adjustable measurement range: pressure range and direction, adjustable through a toggle switch
Zero point adjustment: clearing and calibration
Open the panel and press the zero adjustment button briefly (within 1 second) to reset it.
(Please manually reset while parallel to the installation method; please manually reset while the positive and negative air intakes are connected.)
Operation steps | state | result | key |
1. PCB power on 2. Keep the positive and negative pressure inlet pressure difference at zero 3. Click the 0 button | Red light on | 0 point calibration | |
11、Technical Parameter
Technical Parameter:
measuring range | Refer to "Model Summary" |
Sensing element | Silicon piezoresistive element |
Room temperature | Measurement during correct installation at 20-25 ℃ (FS=full range measurement) |
Precision: Total Error Temperature offset | ± 1 % /± 0.5 % / ±0.2% FS <±0.1% FS /°C |
medium | Air and non corrosive gases |
Permissible medium temperature range | -20-85℃ |
maintenance | long term stability |
Electrical characteristics:
All output types | power supply | safety extra low voltage |
voltage power dissipation | DC16-30V <1.5 VA |
4-20mA type of output | output current | 4-20 mA |
load | ≤250 Ω |
output | Non electric separation, non-polar two wire connection, rectifier bridge anti reverse connection |
link:
Electrical connections |
screw terminal | Maximum 1.5mm ² cable |
cable | Cable sealing gland (without anti cable deformation) |
Pressure connection | Pressure nozzle, 6.21 mm diameter |
ambient condition:
Permissible ambient temperature |
run | -20-85℃ |
Transportation/Storage | -40-125 ℃ |
Permissible environmental humidity | <90 % rh (No condensation) |
12、Appearance dimensions (length * width * height: 99.0 * 101.5 * 39.9mm, tolerance: ± 1mm)
13、Installation method